A mid-cost automated floating chamber system for high-frequency CO2 and CH4 flux measurements: design, calibration, and comparison with infrequent measurement strategies

Ralf C. H. Aben, Judith van der Knaap, Floris Hahn, Gerben Wulterkens, Dániel Szalas-Motesiczky, Emiel Vissers, Arno Engels, Arjan de Kleine, Christian Fritz, and Sarian Kosten

Abstract. Small inland waters are important greenhouse gas (GHG) sources; however, most field campaigns rely on daytime-only measurements collected at multi-week intervals, potentially biasing flux estimates. We present the Buoyant Emission Recorder for Temporal High-Frequency Analyses (BERTHA), a mid-cost automated floating chamber system for high-frequency measurements of CO2 and CH4 fluxes on multiple spatial scales. We describe the system’s design and test how empirically derived pressure and water vapour correction factors for the mid-cost CO2 and CH4 sensors increase the accuracy of reported concentrations and derived flux estimates. Here, we found a 17–37 % (CO2) and 4–9 % (CH4) higher mean flux estimate with pressure compensation during the 97-day measuring period. Compensation for water vapour resulted in much smaller differences (~1–2 % increase). Additionally, we calculated the mean CO2 and CH4 emission using high-frequency measurements during 97 days and simulated alternative measurement scenarios based on the full dataset and evaluated how well these ‘reference means’ could be approached by 1) single, daytime-only chamber flux measurements at daily to monthly intervals, and 2) short-term (2–3 days) automated chamber deployments every two–three weeks combined with machine learning-based gap-filling. Results of the simulation analysis showed that daytime-only measurements consistently and strongly underestimated the reference CO2 mean. CH4 emissions matched the reference mean well for daily, but not for monthly measurements (>90 % and ~23 % of simulations deviated <20 % of the reference mean, respectively). Short-term automated chamber campaigns, gap-filled using machine learning closely reproduced the CO2 reference mean, with 89 % and 48 % of means being within ±20 % of the reference mean, for campaign intervals of two and three weeks, respectively. We conclude that high-frequency chamber measurements using mid-cost GHG analysers combined with empirical pressure corrections provide accurate emission estimates, a robust benchmark for evaluating reduced measurements strategies and gap-filling approaches, and potential for improved process-based understanding of GHG fluxes when combined with ancillary high-frequency measurements.

Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.
Share
Ralf C. H. Aben, Judith van der Knaap, Floris Hahn, Gerben Wulterkens, Dániel Szalas-Motesiczky, Emiel Vissers, Arno Engels, Arjan de Kleine, Christian Fritz, and Sarian Kosten

Status: open (until 19 Nov 2026)

Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor | : Report abuse
  • RC1: 'Comment on egusphere-2026-5600', Anonymous Referee #1, 14 Oct 2026 reply
Ralf C. H. Aben, Judith van der Knaap, Floris Hahn, Gerben Wulterkens, Dániel Szalas-Motesiczky, Emiel Vissers, Arno Engels, Arjan de Kleine, Christian Fritz, and Sarian Kosten
Ralf C. H. Aben, Judith van der Knaap, Floris Hahn, Gerben Wulterkens, Dániel Szalas-Motesiczky, Emiel Vissers, Arno Engels, Arjan de Kleine, Christian Fritz, and Sarian Kosten

Viewed

Total article views: 462 (including HTML, PDF, and XML)
HTML PDF XML Total Supplement BibTeX EndNote
331 93 38 462 45 49 47
  • HTML: 331
  • PDF: 93
  • XML: 38
  • Total: 462
  • Supplement: 45
  • BibTeX: 49
  • EndNote: 47
Views and downloads (calculated since 25 Sep 2026)
Cumulative views and downloads (calculated since 25 Sep 2026)

Viewed (geographical distribution)

Total article views: 462 (including HTML, PDF, and XML) Thereof 462 with geography defined and 0 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Latest update: 16 Oct 2026
Download
Short summary
Greenhouse gas emissions from inland waters vary strongly over space and time, making estimates based on periodic daytime measurements highly uncertain. We developed an automated monitoring system using cost-effective methane and CO2 sensors and improved their accuracy through laboratory calibration and correction methods. Field measurements and simulations show that our system provides reliable emission estimates and that daytime-based CO2 estimates systematically underestimate emissions.
Share