Preprints
https://doi.org/10.5194/egusphere-2026-5280
https://doi.org/10.5194/egusphere-2026-5280
16 Nov 2026
 | 16 Nov 2026
Status: this preprint is open for discussion and under review for Atmospheric Measurement Techniques (AMT).

Validation of diffusive samplers for the simultaneous measurement of nitrogen oxides

Valerio Ferracci, Benjamin Michen, Erin Cackett, Yassine Wakim, Yaser Showman, Thomas G. Holmes, Linda S. Gates, David C. Green, Anja H. Tremper, and Nicholas A. Martin

Abstract. Poor air quality is a major threat to human and ecosystem health, and policies aimed at abating air pollution rely on ambient monitoring to apportion sources, validate inventories and assess the efficacy of interventions. Nitrogen oxides (NOx ≡ NO + NO2) are key air quality pollutants and their monitoring relies on complex and resource-intensive reference instrumentation. Diffusive samplers offer a cost-effective way to monitor NOx across entire localities, overcoming some of the limitations of reference instruments. This study determined the diffusive sampling rates of three types of commercially available samplers (Passam AG's NO2 and NOx samplers, Gradko International's NO2 samplers) and one currently under development (Gradko's NOx samplers). Samplers were exposed monthly at an air quality monitoring station in central London from November 2022 to February 2025. In addition, laboratory exposures of the same sampler types were performed in the Controlled Atmosphere Test Facility (CATFAC). During all exposures, samplers were co-located with reference analysers providing traceable NOx concentrations. After exposure the samplers were returned to the respective manufacturers for chemical analysis, and the reported nitrite results were combined with the reference data and exposure times to determine the experimental NO and NO2 diffusive sampling rates, UNO and UNO2 respectively. Measured diffusive sampling rates at standard conditions (T = 20 °C and p = 101.3 kPa) for the Passam samplers were UNO = (5.67 ± 0.20) × 10−5 m3 h−1 and UNO2 = (4.73 ± 0.11) × 10−5 m3 h−1.  The sampling rate for the new design of the Gradko NO2 sampler (prepared with a 50 % TEA/acetone coating) was  UNO2 = (6.80 ± 0.14) × 10−5 m3 h−1, consistent with that from an earlier design (with 20 % TEA/H2O coating) and indicating that different sorbent recipe had no measurable effect on . UNO for the Gradko samplers was UNO = (1.92 ± 0.20) × 10−5 m3 h−1, below the value expected from molecular diffusivities. Further tests indicated that the oxidant formulation in the Gradko NOx samplers required further optimisation to achieve quantitative conversion of NO to NO2 throughout the exposure period. Storage tests were carried out to establish the effects of time on the extracted nitrite, and indicated good stability of the adsorbed nitrite over timescales of 2–3 months. Analysis of environmental influences showed no significant temperature dependence after normalisation to standard conditions, while evidence was found for minor effects associated with ozone concentrations and high analyte loadings. This work provides traceable validation of diffusive samplers for the simultaneous measurement of NO and NO2 and demonstrates their potential to deliver spatially resolved NOx data for air quality assessment, emissions inventory verification and atmospheric model evaluation.

Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.
Share
Valerio Ferracci, Benjamin Michen, Erin Cackett, Yassine Wakim, Yaser Showman, Thomas G. Holmes, Linda S. Gates, David C. Green, Anja H. Tremper, and Nicholas A. Martin

Status: open (until 21 Dec 2026)

Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor | : Report abuse
Valerio Ferracci, Benjamin Michen, Erin Cackett, Yassine Wakim, Yaser Showman, Thomas G. Holmes, Linda S. Gates, David C. Green, Anja H. Tremper, and Nicholas A. Martin
Valerio Ferracci, Benjamin Michen, Erin Cackett, Yassine Wakim, Yaser Showman, Thomas G. Holmes, Linda S. Gates, David C. Green, Anja H. Tremper, and Nicholas A. Martin

Viewed

Total article views: 50 (including HTML, PDF, and XML)
HTML PDF XML Total BibTeX EndNote
40 7 3 50 7 8
  • HTML: 40
  • PDF: 7
  • XML: 3
  • Total: 50
  • BibTeX: 7
  • EndNote: 8
Views and downloads (calculated since 16 Nov 2026)
Cumulative views and downloads (calculated since 16 Nov 2026)

Viewed (geographical distribution)

Total article views: 50 (including HTML, PDF, and XML) Thereof 50 with geography defined and 0 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Latest update: 17 Nov 2026
Download
Short summary
We evaluated diffusive samplers to measure nitrogen oxides. Sampler performance was characterised using laboratory and field measurements. Results showed good sample stability during storage and limited effects from environmental factors. Overall, this work demonstrates that validated diffusive samplers can complement reference air quality monitoring instruments by providing affordable, spatially detailed air pollution data for local monitoring, model evaluation and emissions assessment.
Share