<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" specific-use="SMUR" dtd-version="3.0" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">EGUsphere</journal-id>
<journal-title-group>
<journal-title>EGUsphere</journal-title>
<abbrev-journal-title abbrev-type="publisher">EGUsphere</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">EGUsphere</abbrev-journal-title>
</journal-title-group>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5194/egusphere-2026-5280</article-id>
<title-group>
<article-title>Validation of diffusive samplers for the simultaneous measurement of nitrogen oxides</article-title>
</title-group>
<contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ferracci</surname>
<given-names>Valerio</given-names>
<ext-link>https://orcid.org/0000-0001-6647-993X</ext-link>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Michen</surname>
<given-names>Benjamin</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Cackett</surname>
<given-names>Erin</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Wakim</surname>
<given-names>Yassine</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Showman</surname>
<given-names>Yaser</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Holmes</surname>
<given-names>Thomas G.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gates</surname>
<given-names>Linda S.</given-names>
</name>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Green</surname>
<given-names>David C.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Tremper</surname>
<given-names>Anja H.</given-names>
</name>
<xref ref-type="aff" rid="aff4">
<sup>4</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Martin</surname>
<given-names>Nicholas A.</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
</contrib-group><aff id="aff1">
<label>1</label>
<addr-line>Air Quality and Aerosol Metrology, National Physical Laboratory, Teddington, TW11 0LW, United Kingdom</addr-line>
</aff>
<aff id="aff2">
<label>2</label>
<addr-line>Passam AG, Schellenstrasse 44, 8708, Männedorf, Switzerland</addr-line>
</aff>
<aff id="aff3">
<label>3</label>
<addr-line>Gradko International Ltd, 77 Wales St, Winchester, SO23 0RH, United Kingdom</addr-line>
</aff>
<aff id="aff4">
<label>4</label>
<addr-line>Environmental Research Group, Imperial College London, 86 Wood Lane, London, W12 0BZ, United Kingdom</addr-line>
</aff>
<pub-date pub-type="epub">
<day>16</day>
<month>11</month>
<year>2026</year>
</pub-date>
<volume>2026</volume>
<fpage>1</fpage>
<lpage>30</lpage>
<permissions>
<copyright-statement>Copyright: &#x000a9; 2026 Valerio Ferracci et al.</copyright-statement>
<copyright-year>2026</copyright-year>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri"  xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p>
</license>
</permissions>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5280/">This article is available from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5280/</self-uri>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5280/egusphere-2026-5280.pdf">The full text article is available as a PDF file from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5280/egusphere-2026-5280.pdf</self-uri>
<abstract>
<p>Poor air quality is a major threat to human and ecosystem health, and policies aimed at abating air pollution rely on ambient monitoring to apportion sources, validate inventories and assess the efficacy of interventions. Nitrogen oxides (NO&lt;em&gt;&lt;sub&gt;x &lt;/sub&gt;&lt;/em&gt;&amp;equiv; NO + NO&lt;sub&gt;2&lt;/sub&gt;) are key air quality pollutants and their monitoring relies on complex and resource-intensive reference instrumentation. Diffusive samplers offer a cost-effective way to monitor NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; across entire localities, overcoming some of the limitations of reference instruments. This study determined the diffusive sampling rates of three types of commercially available samplers (Passam AG&apos;s NO&lt;sub&gt;2&lt;/sub&gt; and NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; samplers, Gradko International&apos;s NO&lt;sub&gt;2&lt;/sub&gt; samplers) and one currently under development (Gradko&apos;s NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; samplers). Samplers were exposed monthly at an air quality monitoring station in central London from November 2022 to February 2025. In addition, laboratory exposures of the same sampler types were performed in the Controlled Atmosphere Test Facility (CATFAC). During all exposures, samplers were co-located with reference analysers providing traceable NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; concentrations. After exposure the samplers were returned to the respective manufacturers for chemical analysis, and the reported nitrite results were combined with the reference data and exposure times to determine the experimental NO and NO&lt;sub&gt;2&lt;/sub&gt; diffusive sampling rates, &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO&lt;/sub&gt; and &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO2&lt;/sub&gt; respectively. Measured diffusive sampling rates at standard conditions (&lt;em&gt;T&lt;/em&gt; = 20 &amp;deg;C and &lt;em&gt;p&lt;/em&gt; = 101.3 kPa) for the Passam samplers were &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO&lt;/sub&gt; = (5.67 &amp;plusmn; 0.20) &amp;times; 10&lt;sup&gt;&amp;minus;5&lt;/sup&gt; m&lt;sup&gt;3&lt;/sup&gt; h&lt;sup&gt;&amp;minus;1&lt;/sup&gt; and &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO2&lt;/sub&gt;&amp;nbsp;= (4.73 &amp;plusmn; 0.11) &amp;times; 10&lt;sup&gt;&amp;minus;5&lt;/sup&gt; m&lt;sup&gt;3&lt;/sup&gt; h&lt;sup&gt;&amp;minus;1&lt;/sup&gt;. &amp;nbsp;The sampling rate for the new design of the Gradko NO&lt;sub&gt;2&lt;/sub&gt; sampler (prepared with a 50 % TEA/acetone coating) was &amp;nbsp;&lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO2 &lt;/sub&gt;= (6.80 &amp;plusmn; 0.14) &amp;times; 10&lt;sup&gt;&amp;minus;5&lt;/sup&gt; m&lt;sup&gt;3&lt;/sup&gt; h&lt;sup&gt;&amp;minus;1&lt;/sup&gt;, consistent with that from an earlier design (with 20 % TEA/H&lt;sub&gt;2&lt;/sub&gt;O coating) and indicating that different sorbent recipe had no measurable effect on . &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO&lt;/sub&gt; for the Gradko samplers was &lt;em&gt;U&lt;/em&gt;&lt;sub&gt;NO&lt;/sub&gt; = (1.92 &amp;plusmn; 0.20) &amp;times; 10&lt;sup&gt;&amp;minus;5&lt;/sup&gt; m&lt;sup&gt;3&lt;/sup&gt; h&lt;sup&gt;&amp;minus;1&lt;/sup&gt;, below the value expected from molecular diffusivities. Further tests indicated that the oxidant formulation in the Gradko NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; samplers required further optimisation to achieve quantitative conversion of NO to NO&lt;sub&gt;2&lt;/sub&gt; throughout the exposure period. Storage tests were carried out to establish the effects of time on the extracted nitrite, and indicated good stability of the adsorbed nitrite over timescales of 2&amp;ndash;3 months. Analysis of environmental influences showed no significant temperature dependence after normalisation to standard conditions, while evidence was found for minor effects associated with ozone concentrations and high analyte loadings. This work provides traceable validation of diffusive samplers for the simultaneous measurement of NO and NO&lt;sub&gt;2&lt;/sub&gt; and demonstrates their potential to deliver spatially resolved NO&lt;em&gt;&lt;sub&gt;x&lt;/sub&gt;&lt;/em&gt; data for air quality assessment, emissions inventory verification and atmospheric model evaluation.</p>
</abstract>
<counts><page-count count="30"/></counts>
<funding-group>
<award-group id="gs1">
<funding-source>Department for Science, Innovation and Technology</funding-source>
<award-id>National Metrology System (NMS)</award-id>
</award-group>
</funding-group>
</article-meta>
</front>
<body/>
<back>
</back>
</article>