Identifying new particle formation events by using a simple and low-cost diffusion charger monitor
Abstract. New particle formation (NPF) is a major source of ultrafine particles (UFPs) in the atmosphere and plays an important role in air quality and human health. NPF events are usually identified from particle number size distribution measured with complex instruments such as the scanning mobility particle sizer (SMPS) and the Neutral cluster and Air Ion Spectrometer (NAIS). The Naneos Partector2 Pro (P2Pro) measures particle number concentrations (PNC) in eight size bins between 7.8 and 382.4 nm using a unipolar diffusion charger. This study investigated whether this simple and lower-cost instrument can be used for detecting NPF events with performance comparable to reference instruments. To do this, we monitored PNC in Brisbane using a P2Pro over a year. A method was developed and validated by comparing the results with previous studies reported in the same area using the NAIS or SMPS. The analysis was carried out under various combinations of three main sets of criteria – the total PNC, the fraction of particles in the nucleation mode, and the times of occurrence of the events. The results, based on the selected criteria showed that NPF events occurred on 158 (44 %) days of the year. The results showed excellent agreement with previous estimates of NPF events at the same location obtained using an SMPS and NAIS. The outcome of this study offers an affordable alternative to an instrument that can detect NPF events that are important in many aspects such as air quality monitoring and health risk assessment.