Vicarious Calibration of 89 GHz Passive Channel in ACTRIS W-band Radar Systems
Abstract. Accurate calibration of remote sensing instruments is fundamental to ensuring data quality and the reliability of retrieved atmospheric products. In the case of passive radiometers, this includes the retrieval of key variables such as the Liquid Water Path (LWP), an important atmospheric quantity governing cloud radiative properties, precipitation processes, and climate feedbacks. This study investigates a vicarious calibration methodology for the 89 GHz passive channel of the cloud radars deployed within the ACTRIS Cloud Remote Sensing (CRS) network with the implicit goal to improve LWP retrievals. Radiative transfer simulations of clear-sky brightness temperatures derived from atmospheric reanalysis profiles are used as independent calibration references. This methodology can be applied to monitor instrument calibration obtained with classic approaches, such as hot/cold reference loads, seamlessly and independently by hardware specifications. The vicarious approach is applied to 12 CRS observatories over a 32-month period (July 2023 to February 2026), combining enhanced clear-sky screening based on radiometric stability and cloud radar observations. Inter-comparison results between ERA5-derived reference brightness temperatures and radiosonde-based estimates, show that 89 GHz passive calibration monitoring can be achieved with an uncertainty within 2 and 4 K, depending on the local orography and the distance between the site under consideration and the radiosonde observations. The analysis further indicates that calibration drifts are predominantly instrument-specific and can change significantly between the manufacturer-recommended six-month calibration cycles. Among other sites considered in the study, the operational impact is demonstrated for L'Aquila site, where the correction mitigates a systematic negative bias, though varying between clear and cloudy conditions. Overall, after applying the correction suggested by our calibration procedure, the occurrences of non-physical negative LWP estimates are reduced from approximately 70 % to 20 %, while in clear-sky periods the correction centers the LWP distribution near zero, reducing the mean error magnitude to roughly one-third. These findings highlight the potential of automated vicarious calibration monitoring across the ACTRIS-CRS network, enabling improved measurement traceability and more reliable cloud microphysical retrievals. The proposed framework also opens new opportunities for transferring calibration information to active radar channels and for enhancing the detection of optically thin liquid clouds through the combined use of 22–31 GHz and 89 GHz observations.
Competing interests: At least one of the (co-)authors is a member of the editorial board of Atmospheric Measurement Techniques.
Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.