the Creative Commons Attribution 4.0 License.
the Creative Commons Attribution 4.0 License.
A magnetite reference material for LA-ICP-MS U–Pb geochronology from the Troodos Ophiolite, Cyprus
Abstract. Magnetite is an increasingly important target material for in situ geochemical analysis and has recently emerged as a promising U–Pb geochronometer. However, the wider application of the method is hindered by the lack of a widely available matrix-matched reference material. Here we propose TR41, a hydrothermal magnetite from the Troodos ophiolite (Cyprus), as a candidate reference material for LA-ICP-MS U–Pb magnetite geochronology. Petrographic, geochemical, and isotopic data demonstrate that TR41 is sufficiently homogeneous for laser ablation analyses and yields clearly defined regressions in Tera–Wasserburg diagram despite U concentrations below 1 µg g-1. As independent ID-TIMS characterisation of magnetite is currently not feasible, the age of TR41 was constrained using complementary geochronological approaches. U–Pb dating of coexisting hydrothermal andradite yields a lower-intercept age of 92.04 ± 2.23 Ma. Assuming that the andradite and magnetite formed during the same hydrothermal event, four blind-test samples containing coexisting magnetite and garnet or apatite were analysed. In all cases, magnetite ages obtained using TR41 as the primary reference material agree, within uncertainty, with independently determined ages of the associated minerals. These results demonstrate that TR41 provides an appropriate matrix correction for LA-ICP-MS U–Pb analyses of magnetite and represents a practical reference material for expanding the magnetite U–Pb geochronology. TR41 is available for distribution to interested laboratories upon request from the corresponding author.
- Preprint
(1338 KB) - Metadata XML
-
Supplement
(131 KB) - BibTeX
- EndNote
Status: open (until 24 Dec 2026)
-
RC1: 'Comment on egusphere-2026-4975', Liam Courtney-Davies, 23 Oct 2026
reply
-
AC1: 'Reply on RC1', Aratz Beranoaguirre, 20 Nov 2026
reply
We would like to thank the reviewer for taking the time to carefully evaluate our manuscript and for providing constructive comments and valuable suggestions, which have helped us to improve the quality and clarity of the paper. Below, we provide a point-by-point response to each of the comments raised.
Beranoaguirre et al. propose a new matrix-matched reference material for LA-ICP-MS U-Pb geochronology of magnetite.
I am supportive of the manuscript overall, and empathise with the authors endeavor to identify and characterize a suitable natural iron oxide RM. There is still a lot more work to be done as the authors state, and this is a start. The manuscript is lacking in parts which can be addressed. I think a major revision is necessary to address missing details. The sentence on line 65 - “We propose that this material may serve as a reference material for method development and inter-laboratory comparison until additional magnetite reference materials become available” should be stated in the abstract.
We thank the reviewer for this suggestion. We have revised the abstract to clarify that TR41 is proposed as a candidate reference material for method development and inter-laboratory comparison until additional magnetite reference materials become available.
It should also be noted that another magnetite U-Pb RM paper has just been published (Jun-Duan et al. 2026, https://doi.org/10.1016/j.gr.2026.09.012). This material is also limited.
The paper by Jun-Duan et al. (2026) was published before our manuscript was submitted, and we have now included it in the revised manuscript. We also acknowledge that the availability of additional magnetite reference materials remains important for further developing and validating the method.
The hydrothermal magnetite RM contender from Cyprus is a mineralogically and chemically heterogenous massive aggregate dominated by magnetite with abundant intergrown mineralogy. This RM candidate differs from typical single grain-type zircon or apatite RMs, however, this is characteristic of iron oxides (particularly those from magmatic-hydrothermal systems where U is sometimes found). The magnetite RM is less than 1 ppm U; the range is not stated in manuscript but is shown to average 0.24 ppm for the RM in the appendix tables.
We agree that its mineralogical composition differs from that of conventional zircon or apatite reference materials (which are usually rich in U, and therefore can be easily dated). However, the presence of multiple crystals is not, in itself, incompatible with its use as a reference material, provided that the target mineral is sufficiently homogeneous at the scale of laser ablation analyses. Similar practical considerations apply to reference materials for other complex matrix types (such as carbonate or garnet), where overall sample heterogeneity does not preclude utility provided the targeted domains are sufficiently homogeneous at the analytical scale of laser ablation. Our petrographic observations, trace-element data and U-Pb analyses indicate that the magnetite population is sufficiently homogeneous for this purpose. We have also clarified the range of U concentrations in the manuscript, which is approximately 0.04-1.1 µg/g, with a mean of 0.24 µg/g.
The authors state that it is unusual to not provide ID-TIMS data for a proposed RM, and provide some fair rationale for why they have not acquired that data, largely because such low-U contents in magnetite seemingly preclude ID-TIMS (it would still be worthwhile to try, has anyone successfully dated magnetite via TIMS this centuary? not that I’m aware). I don’t doubt that the magnetite candidate presented here is near coeval in age to dated coexisting garnet/apatite and this is further supported by magnetite (U-Th)/He data (despite overdispersion as expected), but is that enough for a RM? different reviewers will have differing opinions.
As far as we are concerned (some of the authors have TIMS experience in the past, although not completely up to date with the current techniques), trying it will only be a waste of time. In fact, the paper of Jun-Duan et al. 2026 also does not provide TIMS ages. Likewise, we think that it is a good candidate for RM, although of course it can be substituted for better RMs in the future,as it is stated in the introduction (and after the comment above, also in the abstract).
We acknowledge that an independent ID-TIMS age determination would provide an additional level of validation. However, the very low U concentrations in TR41, combined with the low radiogenic Pb contents and the large Fe matrix, make ID-TIMS analysis particularly challenging. We are not aware of an established, routinely applied ID-TIMS protocol for magnetite that would overcome these limitations, and we therefore consider that attempting such an analysis is unlikely to provide a straightforward independent age determination.
We recognise that the level of characterisation required for a reference material may be subject to different views. Nevertheless, we consider TR41 a suitable candidate matrix-matched reference material, supported by several independent lines of evidence: the U-Pb age of hydrothermal andradite associated with the magnetite, the complementary magnetite (U-Th)/He results, and the agreement between magnetite ages and independently determined garnet or apatite ages in four validation samples. We acknowledge that further testing and the development of additional reference materials are desirable. However, the consistent results obtained across these validation samples support the suitability of TR41 for method development and inter-laboratory comparison, as stated in the revised abstract and Introduction.
Does this present a circular challenge whereby there can never be a ‘true’ magnetite RM, because magnetite does not incorporate much U (if any? there is no mention of how U is hosted in this magnetite - possibly as inclusions given the formation environment). There is no outline or discussion of ablation behavior in these magnetite’s, which almost certainly do not ablate ‘cleanly’ and will differ between formation environment based on the huge variations in magnetite minor and trace element chemistries (see recent in-situ [U-Th]/He papers on different ablation behavior of oxide minerals). Your unknown magnetite’s CB1/CB2 have very high Th/U – are these all just apatite inclusions in magnetite? I don’t think Th should substitute in magnetite(?). You mention some spots being rejected for high Th, maybe some discussion on whether U and Th is lattice bound in magnetite at all is required and what are the ramifications for future magnetite U-Pb.
We thank the reviewer for raising these important questions regarding U and Th incorporation in magnetite and the potential implications for the development of magnetite U-Pb geochronology. We agree that the distribution of U and Th between the magnetite lattice and potential inclusions, as well as the ablation behaviour of magnetite with different compositions and origins, warrant further investigation. However, a detailed assessment of these processes would require a dedicated study and is beyond the scope of the present manuscript, which focuses on evaluating TR41 as a candidate matrix-matched reference material.
Regarding the high Th/U ratios observed in some of the blind-test magnetites, these ratios largely reflect the very low U concentrations rather than exceptionally high Th concentrations. For example, in sample CB-1, the mean Th concentration in magnetite is approximately 0.15 µg/g, compared with approximately 110 µg/g in the associated apatite. Consequently, even a small apatite inclusion could substantially increase the measured Th concentration in a magnetite analysis. Similar effects of mineral inclusions on trace-element concentrations have been discussed by Walters et al. (2026; https://doi.org/10.5194/gchron-7-309-2025), although their study focused on garnet.
Nevertheless, the elevated Th/U ratios alone do not demonstrate the presence of apatite inclusions or establish whether U and Th are structurally incorporated into magnetite. The time-resolved signals of the analysed spots are generally flat (now included in the manuscript, after the reviewer’s comment below), with no clear transient increases indicative of the ablation of discrete inclusions. This observation argues against a significant contribution from inclusions in these analyses, although it cannot completely exclude sub-resolution inclusions or establish the lattice-bound nature of U and Th.
From the probe data, this magnetite looks silician (‘silician magnetite’, See Ciobanu et al. 2019 or Courtney-Davies et al. 2020) – whereby Si is hosted in nano inclusions. This effects ablation behavior and merits further study. This magnetite is zoned; however, your presented images are not high resolution enough to show this – what is the zonation effect? I think more detailed petrography on such heterogenous samples is required in the form of additional figures in the manuscript. You state in the text “High-contrast BSE images reveal oscillatory rims within magnetite grains, which are accompanied by a systematic decrease in Si”. Why are these high contrast images not shown in the manuscript? The very large variations in minor to trace element chemistry from core to rim will create highly variable ablation conditions, unlikely to be matched to an unknown magnetite matrix of a different environment (e.g. BIF v serpentinite). This raises a further question about trying to match one type of magnetite to all magnetite matrices – they simply might be too heterogenous intra-sample/intra-environment.
We thank the reviewer for pointing this out. The image showing the oscillatory zoning was included in an earlier version of the manuscript but removed before the submission. Unfortunately, the corresponding reference to this image was inadvertently retained in the text. We have now reintroduced the image in the revised manuscript to illustrate the oscillatory zoning and the associated decrease in Si towards the grain rims.
Regarding the possible presence of Si-bearing inclusions and their implications for ablation behaviour, we address this point in our response to Comment 3 below.
However, the data from magnetite unknowns is compelling as it gives the ‘correct’ date when normalized to the candidate RM, although no information as far as I can tell is provided for these magnetite unknowns identity apart from ‘skarn’ labelling for one. It should be noted that zircon RMs in Courtney-Davies et al 2020 also gave seemingly ‘correct’ dates for magnetite unknowns when compared with solution standards which gave ‘correct’ dates. The newly published magnetite RM in Jun-Duan et al (2026) also gets ‘correct’ dates using a zircon RM to calibrate magnetite. So, for the level of accuracy/precision required, maybe this RM is enough? hard to tell for sure. To be unequivocal, we need TIMS data as you state.
We agree that the agreement between magnetite ages obtained using TR41 and the independently determined ages of associated minerals is encouraging and suggests that TR41 may be suitable for applications requiring the level of accuracy and precision demonstrated in our study.
However, the fact that non-matrix-matched reference materials have yielded apparently accurate ages in some studies does not demonstrate that matrix effects are negligible or that such calibration approaches are generally reliable. As discussed in the manuscript, several studies have documented significant age biases resulting from the use of non-matrix-matched reference materials, not only for magnetite but also for other minerals, including garnet (Yang et al., 2018; https://doi.org/10.1039/c7ja00315c), carbonate (Parrish et al., 2018; https://doi.org/10.1144/jgs2017-107), cassiterite (Carr et al., 2023) and ilmenite (Thompson et al., 2021). For example, Yang et al. (2018) reported an age offset of approximately 11% for garnet calibrated against zircon, while Parrish et al. (2018) documented biases of approximately 5% in carbonate U–Pb results obtained using zircon-based calibration.
Furthermore, matrix-dependent effects are not restricted to differences between mineral species. Variations in the chemical and structural characteristics of a given mineral can also affect its ablation behaviour and, consequently, the resulting U–Pb data. Metamictisation in zircon, for example, can modify ablation behaviour and affect U–Pb results. Thus, obtaining an age that agrees with an expected geological age does not, by itself, demonstrate that matrix effects are negligible or that a given calibration can be transferred reliably to other samples.
This is also consistent with the reviewer's earlier comment that variations in minor- and trace-element chemistry can produce differences in ablation behaviour.
I believe the thermobarometer has been applied incorrectly, is this not strictly meant to be for magmatic magnetite, not this regressed hydrothermal type (?) – in any case, I don’t think this adds much to the manuscript.
Following the reviewer's comment and further consideration of the applicability and limitations of the thermometric approaches, we have removed the thermometric estimates from the revised manuscript.
To this end, this material should only be considered a ‘secondary’ standard, as the authors more or less state. Finding a suitable ‘true’ natural material is unlikely to work out until the ID-TIMS chemistry is carried out by a willing party.
The term “secondary reference material” implies calibration against an established primary reference material, which is not currently available for magnetite U-Pb geochronology. We therefore consider “candidate reference material” to be the more appropriate designation for TR41 at this stage. We acknowledge that its characterisation remains incomplete, but the agreement obtained in the blind tests supports its potential use for method development and inter-laboratory comparison while further validation and additional reference materials are pursued. We have clarified the scope and limitations of the proposed material in the revised manuscript.
Items to address:
- Images and discussion of ablation pits. How do the pits look, do they contain melt globules? Should there be some discussion of pit geometry and how this might affect analyses? How does the RM compare to unknowns ablation? What are the ablation rates between the RM and different unknowns.
We have added images of the ablation pits in TR41 and one of the validation samples to the revised manuscript. The pits show no apparent evidence of melt-related features, and their geometries are broadly comparable between TR41 and the analysed magnetite samples. These observations suggest similar ablation behaviour under the analytical conditions used.
- Downhole ablation profiles/time resolved analysis spectra, averaged across many spots, would be useful to see.
We have now included representative time-resolved ablation signals in the revised manuscript. The signals are generally relatively flat, suggesting stable ablation behaviour and efficient sample–laser coupling under the analytical conditions used. Furthermore, the absence of significant signal fluctuations indicates that no resolvable inclusions were encountered during these analyses, although sub-resolution inclusions cannot be excluded.
- There are no high res BSE images of the magnetite, I cannot really make out how it looks from the RL alone, I think these samples need much more careful characterization before they can be sent out, the finite images show how texturally complex these samples are, there is no chance that 100 micron diameter spots are not ablating multi domains/inclusions, unless you can demonstrate the opposite with higher resolution images? I know this is annoying but is necessary.
We agree that the textural complexity of TR41 needs to be considered when assessing its suitability as a reference material. However, Figure 2 shows several areas of magnetite sufficiently large to accommodate 100 µm laser spots without visibly intersecting major inclusions or other mineral phases. Although some analyses may intersect minor inclusions, the generally flat time-resolved signals (now included in the manuscript) show no obvious transient signals indicative of discrete inclusions affecting the analyses.
- Show a large scan of a 1x1cm wafer, discuss how many spots and of what size can fit on this wafer, how many times can it be repolished do you think? Up to the author if they want to include this.
The approximately 1 × 1 cm wafers are similar in size to the material shown in Figure 1 and are approximately 0.5-1 cm thick. Wafers with insufficient magnetite for practical use will not be distributed. Given their thickness, the wafers can potentially be repolished multiple times, allowing repeated use. We have clarified these points in the manuscript.
- Why is there such a difference in 238/206 between the grain mount and thin section on the T-W?
The difference in 238U/206Pb ratios between the thin-section and grain-mount analyses reflects variations in the common-Pb contribution. The thin-section analyses include domains with higher common-Pb contents, which results in lower 238U/206Pb ratios. In contrast, the grain-mount analyses generally have a smaller common-Pb contribution, resulting in higher 238U/206Pb ratios. Despite this difference, analyses from both mounts define the same regression line in the Tera-Wasserburg diagram, suggesting the sample isotopic (geochronological) homogeneity.
- Can these validation tests be considered ‘blind’ if you conduct them yourself? semantics maybe, but also similar for describing the material as robust, we cannot say it is robust or that unknowns are giving ‘ages’ without TIMS data, despite me agreeing with you that the RM is probably good enough for the questions in hand.
The fact that the validation analyses were conducted at FIERCE does not, in our view, diminish the validity of these independently calibrated age determinations, as they were obtained using recognised and published reference materials that are independent of our laboratory. We therefore consider the term “ages” appropriate for these results. Nevertheless, acknowledging the reviewer's point, we have adopted the term “dates” for the magnetite results throughout the revised manuscript. We have also moderated our statements regarding the suitability of TR41 as a reference material and replaced the term “robust” with “suitable”.
- You state that the lack of a magnetite RM has hindered the uptake of magnetite U-Pb geochron. I would dispute this, and say the main reason there are few magnetite U-Pb studies, is because most magnetite does not take up U (hence no TIMS), and when it does in hydrothermal environs, it is messy, as your material demonstrates. And that is okay – that is the reality of magnetite containing U.
We agree that the generally low U concentrations in magnetite, particularly in many geological settings, represent an important limitation for U-Pb geochronology. However, previous studies, including those cited in our manuscript, have reported variable and locally sufficient U concentrations in magnetite. We therefore consider that the limited application of magnetite U-Pb geochronology may reflect not only the availability of suitable reference materials but also the analytical challenges associated with measuring very low U and radiogenic Pb concentrations.
At FIERCE, we routinely analyse minerals with exceptionally low U concentrations. For example, Beranoaguirre et al. (2026; https://doi.org/10.5194/gchron-8-495-2026) demonstrated U-Pb dating of garnet with U concentrations below 1 ng/g. Although this does not eliminate the specific challenges associated with magnetite, it illustrates that low U concentrations are not necessarily an analytical obstacle. We agree that magnetite composition and geological origin strongly influence its suitability for U-Pb dating, and we have revised the manuscript to avoid implying that the lack of a reference material is the sole factor limiting the wider application of the method.
- Gelcich et al., 2005 do not date magnetite – this reference should be removed from this context. Same for Tang, they don’t strictly date magnetite.
We agree that Gelcich et al. (2005) investigated a magnetite-apatite assemblage rather than directly dating magnetite, and that Tang et al. (2024) focused on titanomagnetite. We have therefore revised the text to clarify the scope of these studies and to distinguish them from studies that directly applied U-Pb geochronology to magnetite. Gelcich et al. (2005) is now cited in the context of early investigations of magnetite-bearing mineral assemblages, whereas Tang et al. (2024) is explicitly identified as a study of titanomagnetite.
- The recent Watson/Cherniak et al Pb diffusion/closure T in magnetite is omitted from citation and should probably be mentioned (1016/j.chemgeo.2023.121748).
We thank the reviewer for pointing out this study. We have now cited Watson et al. (2023) in the revised manuscript and incorporated their experimental constraints on Pb diffusion in magnetite into our discussion of radiogenic Pb retention and the thermal behaviour of the magnetite U-Pb system.
Citation: https://doi.org/10.5194/egusphere-2026-4975-AC1
-
AC1: 'Reply on RC1', Aratz Beranoaguirre, 20 Nov 2026
reply
Viewed
| HTML | XML | Total | Supplement | BibTeX | EndNote | |
|---|---|---|---|---|---|---|
| 479 | 195 | 33 | 707 | 59 | 34 | 36 |
- HTML: 479
- PDF: 195
- XML: 33
- Total: 707
- Supplement: 59
- BibTeX: 34
- EndNote: 36
Viewed (geographical distribution)
| Country | # | Views | % |
|---|
| Total: | 0 |
| HTML: | 0 |
| PDF: | 0 |
| XML: | 0 |
- 1
Comment on egusphere-2026-4975 Beranoaguirre et al. for GChron.
Beranoaguirre et al. propose a new matrix-matched reference material for LA-ICP-MS U-Pb geochronology of magnetite.
I am supportive of the manuscript overall, and empathise with the authors endeavor to identify and characterize a suitable natural iron oxide RM. There is still a lot more work to be done as the authors state, and this is a start. The manuscript is lacking in parts which can be addressed. I think a major revision is necessary to address missing details. The sentence on line 65 - “We propose that this material may serve as a reference material for method development and inter-laboratory comparison until additional magnetite reference materials become available” should be stated in the abstract.
It should also be noted that another magnetite U-Pb RM paper has just been published (Jun-Duan et al. 2026, https://doi.org/10.1016/j.gr.2026.09.012). This material is also limited.
The hydrothermal magnetite RM contender from Cyprus is a mineralogically and chemically heterogenous massive aggregate dominated by magnetite with abundant intergrown mineralogy. This RM candidate differs from typical single grain-type zircon or apatite RMs, however, this is characteristic of iron oxides (particularly those from magmatic-hydrothermal systems where U is sometimes found). The magnetite RM is less than 1 ppm U; the range is not stated in manuscript but is shown to average 0.24 ppm for the RM in the appendix tables.
The authors state that it is unusual to not provide ID-TIMS data for a proposed RM, and provide some fair rationale for why they have not acquired that data, largely because such low-U contents in magnetite seemingly preclude ID-TIMS (it would still be worthwhile to try, has anyone successfully dated magnetite via TIMS this centuary? not that I’m aware). I don’t doubt that the magnetite candidate presented here is near coeval in age to dated coexisting garnet/apatite and this is further supported by magnetite (U-Th)/He data (despite overdispersion as expected), but is that enough for a RM? different reviewers will have differing opinions.
Does this present a circular challenge whereby there can never be a ‘true’ magnetite RM, because magnetite does not incorporate much U (if any? there is no mention of how U is hosted in this magnetite - possibly as inclusions given the formation environment). There is no outline or discussion of ablation behavior in these magnetite’s, which almost certainly do not ablate ‘cleanly’ and will differ between formation environment based on the huge variations in magnetite minor and trace element chemistries (see recent in-situ [U-Th]/He papers on different ablation behavior of oxide minerals). Your unknown magnetite’s CB1/CB2 have very high Th/U – are these all just apatite inclusions in magnetite? I don’t think Th should substitute in magnetite(?). You mention some spots being rejected for high Th, maybe some discussion on whether U and Th is lattice bound in magnetite at all is required and what are the ramifications for future magnetite U-Pb.
From the probe data, this magnetite looks silician (‘silician magnetite’, See Ciobanu et al. 2019 or Courtney-Davies et al. 2020) – whereby Si is hosted in nano inclusions. This effects ablation behavior and merits further study. This magnetite is zoned; however, your presented images are not high resolution enough to show this – what is the zonation effect? I think more detailed petrography on such heterogenous samples is required in the form of additional figures in the manuscript. You state in the text “High-contrast BSE images reveal oscillatory rims within magnetite grains, which are accompanied by a systematic decrease in Si”. Why are these high contrast images not shown in the manuscript? The very large variations in minor to trace element chemistry from core to rim will create highly variable ablation conditions, unlikely to be matched to an unknown magnetite matrix of a different environment (e.g. BIF v serpentinite). This raises a further question about trying to match one type of magnetite to all magnetite matrices – they simply might be too heterogenous intra-sample/intra-environment.
However, the data from magnetite unknowns is compelling as it gives the ‘correct’ date when normalized to the candidate RM, although no information as far as I can tell is provided for these magnetite unknowns identity apart from ‘skarn’ labelling for one. It should be noted that zircon RMs in Courtney-Davies et al 2020 also gave seemingly ‘correct’ dates for magnetite unknowns when compared with solution standards which gave ‘correct’ dates. The newly published magnetite RM in Jun-Duan et al (2026) also gets ‘correct’ dates using a zircon RM to calibrate magnetite. So, for the level of accuracy/precision required, maybe this RM is enough? hard to tell for sure. To be unequivocal, we need TIMS data as you state.
I believe the thermobarometer has been applied incorrectly, is this not strictly meant to be for magmatic magnetite, not this regressed hydrothermal type (?) – in any case, I don’t think this adds much to the manuscript.
To this end, this material should only be considered a ‘secondary’ standard, as the authors more or less state. Finding a suitable ‘true’ natural material is unlikely to work out until the ID-TIMS chemistry is carried out by a willing party.
Items to address: