Assessing the benefit of sample drying for AE33 aethalometers: evidence from long‑term field observations

Matthew L. Riley and Gunaratnam Gunashanhar

Abstract. Aethalometers measuring equivalent black carbon (eBC) are widely used in both research and regulatory air quality monitoring networks. However, uncertainties regarding the influence of moisture in eBC measurements persist. While many networks recommend or require sample drying, there is limited long‑term field evidence quantifying the benefits of humidity control for aethalometers operated under real‑world conditions. Here we present a multi‑year field intercomparison of aethalometers (AE33, Aerosol Magee Scientific) operated with and without sample drying at an urban background site in Sydney, Australia. Three extended tests (December 2015 – August 2016, November 2016 – June 2017, January 2018 – March 2019) were conducted using four instruments in total. Instruments were co‑located within the same climate‑controlled enclosure and configured identically, differing only in sample humidity conditioning (membrane dryer). Across all tests, wavelengths and averaging periods, strong agreement was observed between dried and non‑dried instruments, with correlation coefficients (R²) consistently exceeding 0.98. For the 880 nm channel, regression slopes for non-dried vs dried sampling ranged from 0.97 – 1.07 across the three tests. Similar results were obtained for 1‑, 2‑, 5‑, and 10‑minute averages, although variability increased at shorter averaging intervals. Stratification by ambient relative humidity, dew‑point temperature, and dew‑point deficit showed no systematic degradation in agreement between hourly averages at high humidity, and moisture‑related effects were small compared with test‑to‑test variability. These results indicate that, for hourly eBC measurements in a temperate, high‑humidity coastal environment, the absence of sample drying introduces only small differences in measured concentrations when compared with humidity‑controlled sampling. While short‑term variability and instrument‑specific effects remain important considerations, these results suggest that long‑term, network‑scale eBC measurements from AE33 aethalometers can remain highly comparable even without sample drying. This study provides quantitative evidence to inform guidance on humidity control for aethalometers in monitoring networks.

Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.
Share
Matthew L. Riley and Gunaratnam Gunashanhar

Status: open (until 10 Sep 2026)

Comment types: AC – author | RC – referee | CC – community | EC – editor | CEC – chief editor | : Report abuse
Matthew L. Riley and Gunaratnam Gunashanhar
Matthew L. Riley and Gunaratnam Gunashanhar

Viewed

Total article views: 79 (including HTML, PDF, and XML)
HTML PDF XML Total BibTeX EndNote
62 10 7 79 5 5
  • HTML: 62
  • PDF: 10
  • XML: 7
  • Total: 79
  • BibTeX: 5
  • EndNote: 5
Views and downloads (calculated since 05 Aug 2026)
Cumulative views and downloads (calculated since 05 Aug 2026)

Viewed (geographical distribution)

Total article views: 20 (including HTML, PDF, and XML) Thereof 20 with geography defined and 0 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Latest update: 10 Aug 2026
Download
Short summary
We tested if drying air samples improves black carbon measurements from AE33 aethalometers. Over three long-term field tests in Sydney, instruments measuring dried and ambient air gave similar results, even during humid conditions. Drying slightly reduced measurement noise and improved data quality for 1-minute averages but had little effect on hourly averages. Our findings suggest that while drying remains best practice, it may provide limited benefit for routine hourly air quality monitoring.
Share