<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" specific-use="SMUR" dtd-version="3.0" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">EGUsphere</journal-id>
<journal-title-group>
<journal-title>EGUsphere</journal-title>
<abbrev-journal-title abbrev-type="publisher">EGUsphere</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">EGUsphere</abbrev-journal-title>
</journal-title-group>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5194/egusphere-2026-6133</article-id>
<title-group>
<article-title>A Traceable Single-Setup Procedure for Simultaneous Static and Dynamic Humidity Calibration: Demonstration on a Broad Range of 48 Commercial Low-Cost Sensors</article-title>
</title-group>
<contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Witt</surname>
<given-names>Felix</given-names>
<ext-link>https://orcid.org/0000-0002-0213-0103</ext-link>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Ebert</surname>
<given-names>Volker</given-names>
<ext-link>https://orcid.org/0000-0002-1394-3097</ext-link>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
<xref ref-type="aff" rid="aff3">
<sup>3</sup>
</xref>
</contrib>
</contrib-group><aff id="aff1">
<label>1</label>
<addr-line>Department of Mechanical Engineering, Institute of Reactive Flows and Diagnostics, Technische Universität Darmstadt, Karolinenplatz 5, 64289 Darmstadt, Germany</addr-line>
</aff>
<aff id="aff2">
<label>2</label>
<addr-line>Institute of Flight Guidance, Technische Universität Braunschweig, Hermann-Blenk-Str. 27, 38108 Braunschweig, Germany</addr-line>
</aff>
<aff id="aff3">
<label>3</label>
<addr-line>Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany</addr-line>
</aff>
<pub-date pub-type="epub">
<day>20</day>
<month>11</month>
<year>2026</year>
</pub-date>
<volume>2026</volume>
<fpage>1</fpage>
<lpage>25</lpage>
<permissions>
<copyright-statement>Copyright: &#x000a9; 2026 Felix Witt</copyright-statement>
<copyright-year>2026</copyright-year>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri"  xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p>
</license>
</permissions>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-6133/">This article is available from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-6133/</self-uri>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-6133/egusphere-2026-6133.pdf">The full text article is available as a PDF file from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-6133/egusphere-2026-6133.pdf</self-uri>
<abstract>
<p>Low-cost relative humidity sensors (LCrHS) are widely used in science, industry, and consumer applications; however, traceable calibration of individual units and proper dynamic characterization are largely unavailable. This work presents a novel calibration procedure, &lt;em&gt;MetDyHuCal&lt;/em&gt;, implemented in our &lt;em&gt;dynH&lt;sub&gt;2&lt;/sub&gt;O&lt;/em&gt; test setup. Our approach enables metrologically traceable, static and dynamic humidity calibration within a single setup and during the same measurement campaign. Our setup is based on two absolute optical hygrometers, &lt;em&gt;SEALDH-II&lt;/em&gt; and &lt;em&gt;MANTA-LAH&lt;/em&gt; as primary, SI-traceable references &amp;ndash; both utilizing &lt;em&gt;direct tunable diode laser absorption spectroscopy&lt;/em&gt; (dTDLAS). The proposed setup and procedure were applied to 48 LCrHS (9 models from 8 manufacturers). Static calibrations reveal substantial sensor model-level offsets and non-linearities, highlighting the necessity for individual correction of each sensor. Dynamic characterizations yields response times that deviate by &amp;minus;50&amp;nbsp;% to +81&amp;nbsp;% from the manufacturer datasheet values. Furthermore, several LCrHS models exhibit a significant, systematic dependence of the measured response time on the absolute humidity level. Together, these results illustrate large performance spreads between nominally identical LCrHS. The reproducibility of the &lt;em&gt;MetDyHuCal&lt;/em&gt; procedure was assessed by repeated characterisations of 10 sensors, each measured five times on different days and after being removed and reinstalled in the setup. The reproducibility test for the characteristic time constant &amp;tau; yielded a median relative standard deviation of 1.0 % (mean 1.3 %). We demonstrate that meaningful, traceable performance figures can be obtained using the proposed standardized procedure. Beyond LCrHS, our approach may also be used to characterize the dynamic behaviour of high-end research instruments, such as &lt;em&gt;HAI&lt;/em&gt;, our multi-channel dTDLAS on the research aircraft &lt;em&gt;HALO&lt;/em&gt;.</p>
</abstract>