<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpublishing3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" specific-use="SMUR" dtd-version="3.0" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher">EGUsphere</journal-id>
<journal-title-group>
<journal-title>EGUsphere</journal-title>
<abbrev-journal-title abbrev-type="publisher">EGUsphere</abbrev-journal-title>
<abbrev-journal-title abbrev-type="nlm-ta">EGUsphere</abbrev-journal-title>
</journal-title-group>
<publisher><publisher-name>Copernicus Publications</publisher-name>
<publisher-loc>Göttingen, Germany</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5194/egusphere-2026-5657</article-id>
<title-group>
<article-title>Surface NMR groundwater measurements with dual transmitters</article-title>
</title-group>
<contrib-group><contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Gul</surname>
<given-names>Sikender</given-names>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Griffiths</surname>
<given-names>Matthew Peter</given-names>
</name>
<xref ref-type="aff" rid="aff2">
<sup>2</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Hardenberg</surname>
<given-names>Michel</given-names>
<ext-link>https://orcid.org/0009-0006-0236-1442</ext-link>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
<contrib contrib-type="author" xlink:type="simple"><name name-style="western"><surname>Larsen</surname>
<given-names>Jakob Juul</given-names>
<ext-link>https://orcid.org/0000-0002-4509-4480</ext-link>
</name>
<xref ref-type="aff" rid="aff1">
<sup>1</sup>
</xref>
</contrib>
</contrib-group><aff id="aff1">
<label>1</label>
<addr-line>Department of Electrical and Computer Engineering, Aarhus University, 8200 Aarhus N, Denmark</addr-line>
</aff>
<aff id="aff2">
<label>2</label>
<addr-line>Hydrogeophysics Group, Department of Geoscience, Aarhus University, 8000 Aarhus C, Denmark</addr-line>
</aff>
<pub-date pub-type="epub">
<day>19</day>
<month>10</month>
<year>2026</year>
</pub-date>
<volume>2026</volume>
<fpage>1</fpage>
<lpage>12</lpage>
<permissions>
<copyright-statement>Copyright: &#x000a9; 2026 Sikender Gul et al.</copyright-statement>
<copyright-year>2026</copyright-year>
<license license-type="open-access">
<license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri"  xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p>
</license>
</permissions>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5657/">This article is available from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5657/</self-uri>
<self-uri xlink:href="https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5657/egusphere-2026-5657.pdf">The full text article is available as a PDF file from https://egusphere.copernicus.org/preprints/2026/egusphere-2026-5657/egusphere-2026-5657.pdf</self-uri>
<abstract>
<p>One of the controlling factors for the depth of investigation in a groundwater measurement with surface NMR is the available excitation current. Increasing this current is generally a difficult and costly engineering challenge. In this paper, we experimentally demonstrate a different approach towards higher excitation currents. We simultaneously operate two surface NMR instruments with overlapping transmitter coils, which effectively turn them into one instrument with a maximum current twice as large as a single instrument. An analysis of the NMR excitation pulses shows that the combined pulses are very stable with negligible amplitude and timing errors. A field example is provided where data from a single instrument and from the dual instrument setup are compared. The paper contains a discussion on how this approach can be extended to novel surface NMR transmitter strategies.</p>
</abstract>
<counts><page-count count="12"/></counts>
<funding-group>
<award-group id="gs1">
<funding-source>Novo Nordisk Fonden</funding-source>
<award-id>NNF22OC0079360</award-id>
</award-group>
</funding-group>
</article-meta>
</front>
<body/>
<back>
</back>
</article>